RS-485 2x2x0.20 PVC
24 AWG/7 Stranded BC, FPE Insulation, Mylar Tape, Overall Shielded, Tinned Copper Braid, PVC Jkt
Datasheet Download
Application
The cable is special designed for BUS system with characteristic impedance of 120ohm. Application for fixed and occasional moving installation.
General
|
Conductor |
24AWG Stranded Bare Copper |
|
Insulation |
Foamed PE |
|
Core Identification |
White, Blue,Orange |
|
Cable Lay-up |
2 Pairs |
| Filler | Cotton Rope |
|
Tape |
Mylar Tape |
|
Shield |
Aluminium Foil |
|
Shield |
85% Braid Coverage, Tinned Copper Wire |
|
Outer Jacket |
PVC |
|
Outer Jacket Colour |
Black(Similar to RAL9004) |
Dimensions
| Conductor Diameter | 7×0.2 mm |
| Insulation Diameter | 1.25 mm |
| Outer Jacket Diameter | 7.20 mm |
| Outer Jacket Thickness | 0.90 mm |
Technical Properties
| Conductor Resistance | ≤ 93.3 Ω/km |
| Dielectric Strength | AC 1.5kV for 1 min |
| Insulation Resistance | ≥ 1000 MΩ x km |
| Characteristic Impedance @ 1 MHz | 120±12Ω |
High Frequency (Nominal/Typical)
|
Frequency |
Attenuation |
| 1 MHz | 30 dB/km |
Physical Properties
|
Min Bending Radius Fixed |
8D Cable Diameter |
|
Min Bending Radius Movement |
15D Cable Diameter |
Standard and Compliance
| Operating Temperature Fixed | -40℃ to +80℃ |
| Installation Temperature | -20℃ to +60℃ |
| Flame Resistance | FT2, IEC 60332-1-2 |
| Oil-Resistant | IRM 902 Oil, 70℃ × 4h (EN 50290-2-22) |
| RoHS | Compliant |
| REACH | Compliant |
| Warranty | 3 years (Indoor) |