OFBP1-24-PV-GRY-Eca (9841)
1 P #24 Str TC, PE Ins, OS+TC Braid, PVC Jkt, CPR Eca
Datasheet Download
Application
RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, ...); Low Voltage Digital Control (24v, …); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc.
General
| Inner Conductor | 24AWG Stranded tinned copper |
| Insulation | HDPE |
| Pairs | 1 |
| Insulation Colour | White/Blue; Blue/White |
| Foil | AL/PET |
| Drain Wire | 24AWG Stranded Tinner Copper |
| Braiding | Tinned Copper Braid 77% coverage |
| Rip Cord | Yes |
| Jacket Colour | Gray (RAL7042) |
| Outer Jacket | PVC |
Dimensions-(mm)
| Conductor Diameter | 7x0.20 |
| Insulation Diameter | 1.75 |
| Nom. Thickness | 0.56 |
| Drain Wire | 7x0.20 |
| Braiding Construction | 16x7/0.10TC |
| Diameter | 5.7 |
| Nom. Thickness | 0.8 |
Electrical Characteristics
| Rated Voltage | 600V |
| Max. Recommended Current [A] | 2.1 Amps per conductor @ 25℃ |
| Nominal Conductor DCR | 86 Ohm/Km |
| Rated Temperature | -30℃ +70℃ |
| UV resistance | ISO 4892-3 |
Standard and Compliance
| CPR Classification | Eca |
| RoHS 3 (EU 2015/863) | Compliant |
| REACH | Compliant |
| Flammability | EN 60332-1-2 |
| Warranty | 3 years (indoor) |