CANBUS FD 4x0.75 PUR Purple Chain
CANBUS FD 4x0.75 PUR Purple Chain Cable Shielded Halogen-free 100m
Datasheet Download
Application
CANBus FD cable is specially designed for data transmission of CANBus system, and can be used for setting upnetworks in various bus systems, especially in the fields of automation technology, integrated control and controller, such as textile industry, construction machinery industry and medical industry. The cable adopts 0.75mm² strandedbare copper conductor with high efficiency shielding, which provides excellent EMC performance and is suitable forfixed applications or occasional movement.
General
| Conductor | Stranded Bare Copper |
| Insulation | Foamed PE |
| Filler | Cotton Rope |
| Tape | Non-woven Tape |
| Core Identification | White,Brown,Yellow,Green |
| Braiding | 85%Braid Coverage,Tinned Copper Wire |
| Jacket | PVC |
| Jacket Colour | Purple (approximate to RAL 4001) |
Dimensions
| Conductor Diameter | 64*0.12mm |
| Insulation Diameter | 2.70mm |
| Jacket Diameter | 9.00mm |
| Jacket Thickness | 1.00mm |
Technical Properties
| Rated Voltage | 300V |
| Conductor Resistance | ≤ 26 Ω/km |
| Dielectric Strength | AC 1500 kV for 1 min. |
| Insulation Resistance | ≥ 5000 MΩ·km |
| Characteristic Impedance | 120±15ohm @ 1.0 MHz |
| Mutual Capacitance | Nom. 35nF/km |
Physical Properties
| Min Bending Radius Fixed | 6D Cable Diameter |
| Min Bending Radius Movement | 12D Cable Diameter |
Standard and Compliance
| Operating Temperature Fixed | -40 ~ +80 ℃ |
| Installation Temperature | -20 ~ +60 ℃ |
| Oil Resistance | IRM 902, 90℃×24 h (IEC-60227-1) |
| Flame Resistance | IEC 60332-1-2 |
| Drag Chain Test | Max.5Million Times; |
| Speed: 1.4m/s (Speed: 70 cycles/min , Length: 0.6m) | |
| RoHS 3 (EU 2015/863) | Compliant |
| REACH | Compliant |
| Warranty | 3 Years (Indoor) |