Product Types

Highlight

PROFINET Type C SF/UTP 4x22AWG/19 PUR Green Chain Cable

PROFINET Type C SF/UTP 4x22AWG/19 PUR Green Chain Cable
PROFINET Type C SF/UTP 4x22AWG/19 PUR Green Chain Cable
icon Datasheet Download

Application

Specially designed for PROFINET protocol, it is used in a wide range of industrial Ethernet applications, such as wiring of machines, equipment, instruments and control cabinets, and its performance conforms to CAT5e.

 

   

General

Conductor  Stranded bare copper
Insulation HDPE
Core Identification White, Blue, Yellow, Orange
Cable Lay-up 4 cores twisted to star quad
Wrapping     Polyester tape
Inner Jacket LSZH
Overall Screen Aluminium foil
Braiding Tinned copper wire, ≥85% coverage
Outer Jacket PUR
Outer Jacket Colour Green, RAL 6018 

  

Dimensions  

Conductor Diameter 19/0.15mm
Insulation Diameter     1.50 mm  
Inner Jacket Diameter  4.00 mm 
Jacket Diameter   6.50 mm
Jacket Thickness 0.70 mm (nom.)

 

Electrical Characteristics  

Conductor Resistance  60 Ω/km (max.)
Resistance Unbalance, core/core 2% (max.)
Resistance Unbalance, pair/pair     5% (max.)
Dielectric Strength   AC 2.0 kV (1 minute)
Insulation Resistance     5000 MΩ x km (min.)
Capacitance Unbalance @ 800 Hz /1000 Hz 1600 pF/km (max.) 
Transfer Impedance      Grade 1 (IEC 61156-5) 
Coupling Attenuation  ≥ 80 dB (30 MHz to 100 MHz) 
Data Transmission IEC 61156-5 (Category 5E)
Delay Skew ≤ 20 ns/100 m

   

Mechanical Characteristics

Operating Temperature -40˚C to +80˚C (fixed)
Operating Temperature -20˚C to +60˚C (movement)
Installation Temperature -20˚C to +60˚C
Minimum Bending Radius 4 x cable Ø (fixed) 
Minimum Bending Radius   8 x cable Ø (movement)
Operating Voltage     600 V
Oil Resistance  IRM 902 oil, 100˚C x 96h (UL758)
UV Resistance  300 h (UL 1581) 
Pull Tension  50 N (max.) 
Pressure Test  3000 N (max.) 

 

Standard and Compliance         

CPR Classification     Eca
Halogen Free IEC 60754-1
Flammability IEC 60332-1-2, FT2
RoHS 3 Compliant Yes
REACH Compliant Yes
Warranty 3 years (indoor)