PROFINET Type A SF/UTP 4x22AWG/1 LSZH Green Fixed
PROFINET Type A SF/UTP 4x22AWG/1 LSZH Green Fixed
Datasheet Download
Application
Specially designed for PROFINET protocol, it is used in a wide range of industrial Ethernet applications, such as wiring of machines, equipment, instruments and control cabinets, and its performance conforms to CAT5e.
General
| Conductor | Solid bare copper |
| Insulation | HDPE |
| Core Identification | White, Blue, Yellow, Orange |
| Cable Lay-up | 4 cores twisted to star quad |
| Wrapping | Polyester tape |
| Inner Jacket | LSZH |
| Overall Screen | Aluminium foil |
| Braiding | Tinned copper wire, ≥85% coverage |
| Outer Jacket | LSZH |
| Outer Jacket Colour | Green, RAL 6018 |
Dimensions
| Conductor Diameter | 0.645 mm |
| Insulation Diameter | 1.48 mm |
| Inner Jacket Diameter | 4.00 mm |
| Jacket Diameter | 6.50 mm |
| Jacket Thickness | 0.70 mm (nom.) |
Electrical Characteristics
| Conductor Resistance | 57.5 Ω/km (max.) |
| Resistance Unbalance, core/core | 2% (max.) |
| Resistance Unbalance, pair/pair | 5% (max.) |
| Dielectric Strength | AC 2.0 kV (1 minute) |
| Insulation Resistance | 5000 MΩ x km (min.) |
| Capacitance Unbalance @ 800 Hz /1000 Hz | 1600 pF/km (max.) @ 800 Hz or 1000 Hz |
| Transfer Impedance | Grade 1 (IEC 61156-5) |
| Coupling Attenuation | ≥ 80 dB (30 MHz to 100 MHz) |
| Data Transmission | IEC 61156-5 (Category 5E) |
| Delay Skew | ≤ 20 ns/100 m |
Mechanical Characteristics
| Operating Temperature | -40˚C to +80˚C (fixed) |
| Installation Temperature | -20˚C to +60˚C |
| Minimum Bending Radius | 6 x cable Ø (fixed) |
| Operating Voltage | 600 V |
| Pull Tension | 50 N (max.) |
| Pressure Test | 3000 N (max.) |
Standard and Compliance
| CPR Classification | Eca |
| Flammability | IEC 60332-1-2, FT2 |
| RoHS 3 Compliant | Yes |
| REACH Compliant | Yes |
| Warranty | 3 years (indoor) |