Product Types

Highlight

F/FTP Cat6A LSZH B2ca

F/FTP Cat6A LSZH B2ca
F/FTP CAT6A, 23AWG Solid Conductor, LSZH Jacket, CPR B2ca
icon Datasheet Download

Application

Horizontal and building backbone Cable, support current and future category 6A applications: such as 10GBase-T (10 Gigabit Ethernet), 1000Base-T (Gigabit Ethernet), 100 Base-T, 10 Base-T, ISDN, ATM as well as PoE application etc

 

General

Cable Type Category 6A
Operating Frequency 500 MHz Max.
Conductor Solid Copper
Number of Pairs 4
Insulation Material     SKS-PE
Insulation Colour Blue, White/Blue; Orange, White/Orange; 
  Green, White/Green; Brown, White/Brown
Shielding Each Pair with Individual Aluminium Foil
Drain Wire Tinned Copper
Overall shielding Aluminium foil
Rip Cord      Yes
Jacket Material LSZH
Jacket Colour Customization

  

Dimensions

Conductor Diameter 0.56 mm
Insulation Diameter 1.32 mm
Insulation Thickness 0.38 mm
Drain Wire Diameter     0.40 mm
Diameter over Jacket 7.20 mm
Jacket Wall Thickness 0.60 mm

 

Electrical Characteristics

Transmission Standards ANSI/TIA-568.2-D | ISO/IEC 11801 Class EA | EN 50173-1
Operating Voltage     80 V Max.
Characteristic Impedance 100 ± 15 Ohms
  100 ± 22 Ohms (100-200MHz)
  100 ± 32 Ohms (200-500MHz)
Conductor DC Resistance 93.8 Ohms/ km
DC Resistance Unbalance 3 % Max.
Insulation Resistance     5000 MOhms/km Min.
Dielectric Strength 1500 Vac | 2500 Vdc Min.
Mutual Capacitance 5.6 nF/100m
Pair to Ground Capacitance Unbalance 330 pF/100m
Velocity of Propagation 69 % Nominal
  Delay Skew 45 ns Max.

 

Mechanical Characteristics

  Operating Temperature -30℃ to +70℃  
Bend Radius (Stationary | Installation) 36 mm | 73 mm   
Pull Tension 100 N Max.
Before Aging  
           Tensile Strength ≥9.5 Mpa
           Elongation ≥125 %  
After Aging(110℃±2℃,168h)  
           Tensile Strength ≥70 % of Unaged
           Elongation ≥70 % of Unaged
UV Resistance ISO4892-3 (500 Hours)  

  

Standard and Compliance 

CPR Classification B2ca
Flammability EN 60332-1-2
Reaction to Fire - Bundle Flame Test EN 50399
Halogen Acid Gas Test IEC 60754-2
Smoke Density Test  IEC 61034-2
RoHS 3 (EU 2015/863) Compliant
REACH Compliant
Warranty 3 Years (Indoor/Outerdoor)