ETHERNET CAT7 S/FTP 4x2x23AWG/1 PVC Yellow Fixed
ETHERNET CAT7 S/FTP 4x2x23AWG/1 PVC Yellow Fixed
Datasheet Download
Application
This is a cable with 100 Ω characteristic impedance for data transmission, double screened design supported excellent EMC performance, used for fixed installation application.
General
| Conductor | Stranded bare copper |
| Insulation | Foam PE |
| Core Identification | White, Blue, White, Orange |
| White, Green, White, Brown | |
| Individual Screen | Aluminium foil |
| Braiding | Tinned copper wire, ≥85% coverage |
| Outer Jacket | PVC |
| Outer Jacket Colour | Yellow, RAL 1021 |
Dimensions
| Conductor Diameter | 0.56 mm |
| Insulation Diameter | 1.34 mm |
| Jacket Diameter | 8.20 mm |
| Jacket Thickness | 0.65 mm (nom.) |
Electrical Characteristics
| Conductor Resistance | 93.8 Ω/km (max.) |
| Resistance Unbalance, within a pair | 2% (max.) |
| Resistance Unbalance, between pairs | 5% (max.) |
| Dielectric Strength | DC 1.0 kV (1 minute) |
| Insulation Resistance | 5000 MΩ x km (min.) |
| Capacitance Unbalance @ 800 Hz /1000 Hz | 1600 pF/km (max.) |
| Transfer Impedance | Grade 1 (IEC 61156-5) |
| Coupling Attenuation | Type IB (IEC 61156-5) |
| Data Transmission | IEC 61156-5 |
| Delay Skew | 25 ns/100m (max.) |
| Rated Voltage | 30 V |
Mechanical Characteristics
| Operating Temperature | -40˚C to +80˚C (fixed) |
| Installation Temperature | -20˚C to +60˚C |
| Minimum Bending Radius | 8 x cable Ø (fixed) |
Standard and Compliance
| CPR Classification | Eca |
| Flammability | IEC 60332-1-2, FT2 |
| RoHS 3 Compliant | Yes |
| REACH Compliant | Yes |
| Warranty | 3 years (indoor) |