Product Types

Highlight

RG677STVB

RG677STVB
RG-6, 77% Tri-Shield, Black PV
icon Datasheet Download

General

Inner Conductor Copper Clad Steel (21% CCS)
Insulation Foamed PE
First Shield AL/PET/AL Bonds to Dielectric
Second Shield 77% Braid Coverage, Al wire
Third Shield AL/PET
Outer Jacket PVC
Jacket Colour Black

 

Dimensions

Conductor Diameter 1.02 mm
Insulation Diameter 4.55 mm
Foil Overlap 18 - 35%
Foil OD 4.78 mm
Braiding Wire OD 0.16 mm
Diameter over Jacket 7.06 mm
Jacket Wall Thickness 0.76 mm

 

Electrical Characteristics

Operating Temperature -20℃ to +70℃
Dielectric Adhesion to Conductor 10-25LB/2”
Characteristic Impedance 75 ± 3 Ohms
Conductor DC Resistance ≤102 Ohms/km
Loop Resistance ≤120 Ohms/km
Velocity of Propagation 82%
Return Loss, 5-1000 MHz ≥20 dB
Return Loss, 1000-3000 MHz ≥15 dB
UV Resistance UL1581

Max. Attenuation @ 68°F (20°C)

Frequency

(MHz)

Attenuation

(dB/100m)

Frequency

(MHz)

Attenuation

(dB/100m)

Frequency

(MHz)

Attenuation

(dB/100m)

Frequency

(MHz)

Attenuation

(dB/100m)

5

2.62

350

12.63

870

20.04

1700

28.54

55

5.25

400

13.61

1000

21.49

1800

29.43

211

10.00

450

14.43

1218

23.65

2000

31.17

250

10.82

500

15.29

1300

24.70

2200

32.84

270

11.04

550

16.08

1400

25.72

2500

35.20

300

11.64

600

16.73

1500

26.67

2800

37. 47

330

12.26

750

18.54

1600

27.62

3000

38.91

 

Standard and Compliance

CPR Classification Eca
Flammability IEC 60332-1-2
RoHS 3 (EU 2015/863) Compliant
REACH Compliant
Warranty 3 Years (Indoor)