Application
This is a cable with 100 Ω characteristic impedance for data transmission, Individual and collective screened lan-cable support excellent EMI performance.
General
| Conductor | Stranded bare copper |
| Insulation | Foam PE |
| Core Identification | White, Blue, White, Orange |
| White, Green, White, Brown | |
| Individual Screen | Aluminium foil |
| Braiding | Tinned copper wire, ≥85% coverage |
| Outer Jacket | PUR |
| Outer Jacket Colour | Yellow, RAL 1021 |
Dimensions
| Conductor Diameter | 7/0.16 mm |
| Insulation Diameter | 1.00 mm |
| Jacket Diameter | 6.50 mm |
| Jacket Thickness | 0.70 mm |
Electrical Characteristics
| Conductor Resistance | 148 Ω/km (max.) |
| Resistance Unbalance, within a pair | 5% (max.) |
| Dielectric Strength | DC 1.0 kV (1 minute) |
| Insulation Resistance | 5000 MΩ x km (min.) |
| Data Transmission | ANSI/TIA-568.2-D |
| Rated Voltage | 30 V |
| Characteristic Impedance | 100±15 ohm @100MHz |
Mechanical Characteristics
| Operating Temperature | -40˚C to +80˚C |
| Installation Temperature | -20˚C to +60˚C |
| Minimum Bending Radius | 5 x cable Ø (fixed) |
| Oil Resistance | IRM 902 oil, 90˚C x 24h (EN 50227-1) |
| UV Resistance | UL 1581 section 1200 |
Standard and Compliance
| CPR Classification | Eca |
| Flammability | IEC 60332-1-2 |
| RoHS 3 Compliant | Yes |
| REACH Compliant | Yes |
| Warranty | 3 years (indoor) |