Product Types

Highlight

CANBUS TP 1x2x0.22 PVC Purple

CANBUS TP 1x2x0.22 PVC Purple
CANBUS TP 1x2x0.22 PVC Purple Shielded 100m
icon Datasheet Download

Application

CANBus TP cable is specially designed for data transmission of CANBus system, and can be used to set up networks in various bus systems, especially in the fields of automation technology, integrated control and controller, such as textile industry, construction machinery industry and medical industry. The cable adopts 0.22mm² stranded bare copper conductor with high efficiency shielding, which provides excellent EMC performance and supports fixed installation applications.

 

General

Conductor Stranded Bare Copper
Insulation  Foamed PE
Filler PP yarn
Tape Mylar Tape
Core Identification White,Brown
Braiding 85%Braid Coverage,Tinned Copper Wire
Jacket PVC
Jacket Colour Purple (approximate to RAL 4001)

 

Dimensions

Conductor Diameter 7*0.20 mm
Insulation Diameter 1.70 mm
Jacket Diameter 5.90mm
Jacket Thickness 1.00 mm

 

Technical Properties

Rated Voltage 300V
Conductor DC Resistance ≤ 93.8 Ω/km
Dielectric strength AC 2.0KV for 1 min.
Insulation Resistance ≥ 5000 MΩ·km
Capacitance @800 Hz or 1000 Hz ≤ 60 pF/m
Velocity of Propagation Nom. 70%
Characteristic Impedance 120±15 Ω at 1.0 MHz
Attenuation Nom. 0.60 dB/100m at 100 kHz
  Nom. 1.70 dB/100m at 1 MHz
  Nom. 3.90 dB/100m at 5 MHz
  Nom. 5.60 dB/100m at 10 MHz
  Nom. 8.10 dB/100m at 20 MHz
Transfer Impedance ≤ 250 mΩ/m at 30 MHz

 

Physical Properties

Min Bending Radius Fixed 5D Cable Diameter
Min Bending Radius Movement 10D Cable Diameter

 

Standard and Compliance 

Operating Temperature Fixed  -40 ~ +80 ℃
Installation Temperature -20 ~ +60 ℃
Flame Resistance IEC 60332-1-2 , VW-1
Oil Resistance IRM 902, 70℃×4h (EN 50290-2-22)
Sunlight Resistance 300 h (UL1581)
RoHS 3 (EU 2015/863)  Compliant
REACH Compliant
Warranty 3 Years (Indoor)