Product Types

Highlight

677TSV-5E-G2-VG

677TSV-5E-G2-VG
Hybrid Cable, 2xCAT5E+2xRG6+G657A1 Fiber cable, Grey PVC Jacket, CPR Eca
icon Datasheet Download

Cross-sectional View

 

General

A (1x Fiber cable)   
No. of Cables 
Cable Colour

1

Orange

B (2 x Data Cable)   
No. of Cables 
Cable Colour

2

Grey, Blue

C (2 x Coaxial Cable)   
No. of Cables 
Cable Colour

2

White, Black

Overall  
Wrapping 
Rip Cord 
Jacket Material 
Jacket Colour 
Jacket Thickness 
Overall Diameter
PET Foil
Yes
PVC
Grey
1.00 mm
16.00 ±0.50 mm

 

Standard and Compliance

CPR Classification Eca
Flammability EN 60332-1-2
RoHS 3 (EU 2015/863) Compliant
REACH Compliant
Warranty 3 Years (Indoor)

  

Fiber cable, G657A1, tight-buffer, Aramid yarns, LSZH jacket

 

Cross-sectional View

 

 

Gener al

Glass Type G657A1
Fiber Count 2
Tight-Buffer LSZH
Strength Member Aramid yarns
Jacket Material LSZH
Jacket Colour Orange

 

Dimensions

Tight-Buffer Diameter 0.90 mm
Jacket Diameter 3.00 mm

 

Mechanical Characteristics

Operating Temperature -20℃ to +70℃

 

U/UTP CAT6, 24AWG Solid Conductor, LSZH Jacket

 

Application

Category 5e applications, such as: 100BaseTX, 100BaseVG NTSC/PAL, Component or Composite Video, AES/EBU, Digital Video, RS-422, PoE

 

General

Cable Type Category 5E
Operating Frequency 100 MHz Max.
Conductor Solid Copper
Number of Pairs 4
Insulation Material HDPE
Insulation Color Blue, White/Blue; Orange, White/Orange; 
  Green, White/Green; Brown, White/Brown
Rip Cord Yes
Jacket Material PVC

 

Dimensions

Conductor diameter 0.45 mm
Insulation diameter 0.83 mm
Insulation thickness 0.19 mm
Diameter over jacke 4.70 mm
Jacket wall thickness 0.50 mm

 

Electrical Characteristic

Transmission Standards ANSI/TIA-568.2-D (100M FLUKE CHANNEL)
Operating Voltag 80 V Max.
Characteristic Impedance 100 ± 15 Ohms
Conductor DC Resistance 115 Ohms/ km
DC Resistance Unbalance 3 % Max.
Insulation Resistance 5000 MOhms/km Min.

Dielectric Strength

1500 Vac | 2500 Vdc Min.

Mutual Capacitance 5.6 nF/100m
Pair to Ground Capacitance Unbalance 330 pF/100m
Velocity of Propagation 69 % Nominal
Delay Skew 45 ns Max.

 

Mechanical Characteristics

Operating Temperature -20℃ to +70℃
Bend Radius (Stationary | Installation) 24 mm | 48 mm
Pull Tension 100 N Max.
Before Aging  

Tensile Strength

Elongation

≥13.8 Mpa

≥200 %

After Aging(110℃±2℃,168h)  

Tensile Strength

Elongation

≥80 % of Unaged

≥80 % of Unaged

UV Resistance ISO4892-3 (500 hours)

 

RG-6, 77% TRI-SHIELD, LSZH Jacket, CLASS A+

 

General

Inner Conductor Solid Copper
Insulation Foam PE
First Shield AL/PET/AL bonds to Dielectric
Second Shield 77% Braid coverage, Al wire
Third Shield AL/PET/AL
Outer Jacket PVC

 

Dimensions

Conductor diameter 1.02 mm
Insulation diameter 4.57 mm
Foil Overlap 18 - 35%
Foil OD 4.78 mm
Diameter Over Jacket 6.86 mm
Jacket wall thickness 0.76 mm

 

Electrical Characteristic

Operating temperature -20℃ to +60℃
Characteristic Impedance 75 ± 3 Ohms
DC resistance inner conductor ≤22 Ohms/km
DC resistance shield conductor ≤20 Ohms/km
Velocity of Propagation 82%
Return Loss, 5-470 MHz ≥23 dB
Return Loss, 470-1000 MHz ≥20 dB
Return Loss, 1000-2000 MHz ≥18 dB
Return Loss, 2000-3000 MHz ≥16 dB
Transfer Impedance, 5-30MHz ≤2.5 mΩ/m
SHIELDING, 30-1000MHz ≥95 dB
SHIELDING, 1000-2000 MHz ≥85 dB
SHIELDING, 2000-3000MHz ≥75 dB
UV Resistance ISO4893-3 (500 hours)

Max. Attenuation @ 68°F (20°C)

Frequency

(MHz)

Attenuation

(dB/100m)

Frequency

(MHz)

Attenuation

(dB/100m)

Frequency

(MHz)

Attenuation

(dB/100m)

Frequency

(MHz)

Attenuation

(dB/100m)

5

1.90

350

12.63

870

20.04

1700

28.54

55

5.25

400

13.61

1000

21.49

1800

29.43

211

10.00

450

14.43

1218

23.65

2000

31.17

250

10.82

500

15.29

1300

24.70

2200

32.84

270

11.04

550

16.08

1400

25.72

2500

35.20

300

11.64

600

16.73

1500

26.67

2800

37.47

330

12.26

750

18.54

1600

27.62

3000

38.91