Product Types

Highlight

KX895VG

KX895VG
KX8, STANDARD BC Conductor, HDPE Insulation, 95% CCAM BRAID, PVC Jkt
icon Datasheet Download

General

Inner Conductor Stranded Bare Copper
Insulation HDPE
Shield 95% Braid Coverage, CCMA wire
Power Core Copper Clad Aluminium
Outer Jacket PVC
Jacket Colour Green

 

Dimensions

Conductor Diameter 7×0.40 mm
Insulation Diameter 7.24 mm
Insulation Thickness 3.02 mm
Shield Construction 168×0.12 mm
Diameter over Jacket 10.15 mm
Jacket Thickness 1.34 mm

 

Electrical Characteristics

Operating Temperature -20℃ to +70℃
Impedance 75±2 Ohms
Propagation Velocity ≥66%
Capacitance 67pF/m
Return Loss, 30-300 MHz ≥20 dB
Return Loss, 300-3000 MHz ≥20 dB

Max. Attenuation @ 68°F (20°C)

Frequency

(MHz)

Attenuation

(dB/100m)

Frequency

(MHz)

Attenuation

(dB/100m)

5

1.6

400

17.30

50

5.50

800

24.50

200

11.60

 

 

 

Standard and Compliance

RoHS 3 (EU 2015/863) Compliant
REACH Compliant
Warranty 3 Years (Indoor)