How a Network Cable B2ca Is Built for Automation and Audio


The Network Cable B2ca on this page is the OFBP2-22-PH black B2ca model, code 3107A, from Hangzhou Sanyuan Cable Co., Ltd. The page describes a 2 pair #22 cable with a shield, foam PE insulation, a tinned copper braid, a low smoke halogen free jacket and a B2ca s1a,d0,a1 flame rating. It lists factory and process automation, video, audio and data communication as the applications. The page gives a full construction and electrical table, but it does not give a reel length, a packing method or a price.

The OFBP2-22-PH Cable

The page gives a 22AWG stranded tinned copper inner conductor and a foam PE insulation. It lists 2 pairs with white/blue and blue/white, then white/orange and orange/white insulation colours, and a colour list of blue RAL 5015, white RAL 9010 and orange RAL 2003. The cable has an AL/PET foil, a 22AWG stranded tinned copper drain wire, a tinned copper braid with 65 percent coverage and a white rip cord. A buyer should confirm the pair count and the colour code against the project wiring schedule.

The page gives a conductor diameter of 7 by 0.254mm, an insulation diameter of 2.20mm and a nominal insulation thickness of 0.71mm. The drain wire is 7 by 0.254mm, the braid is 16 by 8/0.11 and the jacket diameter is 9.1mm with a nominal thickness of 1.2mm. The jacket colour is black RAL9011 and the outer jacket is low smoke halogen free. The page does not give a minimum bend radius, a cable weight or a pulling tension. Those values should be requested for an installation.

Electrical Data

The page gives a rated voltage of 450/750V and a maximum recommended current of 4.8A per conductor at 25 degrees Celsius. It gives a nominal DC resistance of 60 ohm per km maximum at 20 degrees Celsius and an insulation resistance of 200 megohm km maximum. The impedance is 120 plus or minus 15 ohm. A buyer should ask for the impedance test method and the frequency band, because a 120 ohm cable is often used for a specific bus or audio application.

The page gives a rated temperature of -30 to +70 degrees Celsius and a UV resistance to ISO 4892-3. It does not give a fire survival time or a circuit integrity rating. The buyer should ask for the fire test data if the cable is for a life safety circuit. The page does not give a halogen content or a smoke index. The buyer should ask for the EN 60754 and EN 61034 reports. The page does not give a dielectric strength test voltage, so the buyer should request the routine test data.

Compliance

The page gives a CPR classification of B2ca s1a,d0,a1. It also lists RoHS 3 under EU 2015/863 and REACH as compliant, with a flammability test to EN 60332-1-2, a smoke density test to EN 61034-2, a halogen acid gas test to IEC 60754-1 and a corrosive gas test to IEC 60754-2. The page also lists a fire reaction flame beam test. A buyer should ask for the CPR declaration and the test report for the exact model, because the B2ca class is the key selling point.

The page does not give a third party lab name or a certificate number. A buyer should ask for the CPR test report and the factory production control certificate. The page does not give a CE declaration of performance. The buyer should ask for the DoP and the AVCP system for the target market. The page does not give an LPCB or a UL listing. For a data centre or a tunnel, the buyer should confirm the local fire code and the required class before the order.

Ordering and Contact

The page does not give a price, a minimum order, a lead time or a reel length. A buyer should send the pair count, the conductor, the shield, the jacket, the CPR class, the length and the destination, and ask for a quotation with the test report and the reel data. The page does not give a packing method. The buyer should confirm the reel size, the drum return and the cable end sealing. The page does not give a cut length service, so the buyer should ask before the order.

The page does not give a contact e-mail or a phone number in the extracted text. The site has a contact page, a cable laboratory page and a quality control page. A buyer should request the factory address, the certificate list and the sample. For a first order, a sample of the Network Cable B2ca and a CPR report review are the practical way to check the construction, the impedance and the fire class before a project order.